PIT-S206R026H-0302-L-K / UMF2-D14G0BK3   - Kobold Danmark (Denmark)  Sales

BRAND Kobold
Product PIT-S206R026H-0302-L-K / UMF2-D14G0BK3
Description magnetic inductive flowmeter
Internal code IMP554530
Weight 1
Technical specification Electro-Magnetic-Flowmeter Model-Code Sensor : PIT-S206R026H-0302-L-K Model-Code Transmitter : UMF2-D14G0BK3 Function Measuring principle : pulsed DC field Operating conditions Flow range [m3/h] : inner diameter needed Fluid : fluid Density [kg/m3] : 1000 Operating temp. [°C] : max. 100 Operating press. [bar g] : max. 16 Flow direction : - please state Sensor informations Wetted parts : SS 1.4571/1.4404/PTFE Process connection : 2" CLASS 150 RF ASME B16.5 Nominal pressure : 16 bar Sensor length "T" : 263 mm (DN700-DN1200) Electrodes : Hastelloy C-4 Earthing electrode : without Ingress protection : IP65 Connection to sensor : separate - terminal box via M20x1,5 Approval : without Fluid temperature limit : 100 °C Staight inlet run : 10 x DN Straight outlet run : 5 x DN Transmitter informations (UMF2) Mounting : separate (-40°C to 100°C Med. temp.) Ingress protection : IP67 Conduit port opening : M20x1,5 Approval : without Explosion proof : without Display : LCD Power supply : 24V DC (+20/-10%) Current output : 4-20 mA with HART®-Protocol Pulse output : passive 24V DC Status output : passive 24V DC forward-/backward flow detection MIN/MAX flow, alarm Ambient temperature : -20 bis 60°C Performance characteristics Accuracy : +/- 1,5% of actual flow +/- 0,5% of full scale Min. conductivity min : 20 μS/cm (100 μS/cm with empty pipe detection) Accessories : - with special coils for low velocities of 0,5 -5 m/s - 15 m cable IP67 incl. junction-box on transmitter - including test-report 2.2

Please send us your request per e-mail, so we can send you our offer with competitive prices and delivery time for Kobold - PIT-S206R026H-0302-L-K / UMF2-D14G0BK3 magnetic inductive flowmeter number or any other model you need. We can offer competitive price, and delivery time with wide products distribution network in Danmark (Denmark) Industrial products Market.

WE SELL ONLY NEW AND ORIGINAL PRODUCTS!

More products of Kobold

US-TS-3000-25-M.2

uLTRASONIC EMITTER

VK 150

vacuum cleaner

VKA-210500R20B

Flowmeter Type: MCA-Z independent of viscosity execution: brass, measuring range: 5-16 l / min compliant oil without contact terminal to reduce G3 / 4 IG flow direction from bottom to top RoHS standard design

VKA-2106-00R25B

Flowmeter 10-32 l / min oil

VKA-3102-R0R25B

Flowmeter / guard, from 0.35 to 1.25 l / min oil

VKA-3104R0R25B

Flowmeter guardian Type: MCA ZR independent of viscosity Model: Brass RANGE: 2 - 6 1 / min oil Normally open Max. 250 V - 100 VA - 1.5 A G1 IG Standard without reduction

VKA-3104UOR15R

Flowmeter / guardian, Type: MCA-ZR, brass embodiments, range 2-6 l./min oil, max.240V / 60VA / 1A, connection with ReduzierungG 1/2 IG, from right to left

VKA-3105R0R25B

Flowmeter guardian Type: MCA ZR independent of viscosity Model: Brass measuring range: 5-16 1 / min oil Normally open Max. 250 V - 100 VA - 1.5 A G1 IG Standard without reduction

VKA-3105-R0R25B

Flowmeter / guardian, 5-16 l / min oil

VKA-3106R025B

(Flowmeter / valve type: MCA ZR independent of viscosity version: brass Measurement range: 10-32 l / min oil closing contact max 250 V / 100 VA / 1.5 A connection G1 IG standard without reducing the flow direction from bottom to top RoHS compliant standard.)

VKA-3106U0R25L

(Flowmeter / guardian Type: MCA-ZR)

VKG-2107XXR15

ERS-F2 Erastzteil Replacement measuring glass for VCG - 2107xxR15 incl.Dichtungen Perbunan (NBR)

VKG-2108U0R20

Flowmeter / guardian viscosity compensated in the range 1 ... 540 mm2 / s Mounting position any Material brass, glass NBR, oxide Mb: 2,5..45 l / min oil Max. 12 bar; Max. 100 C.

VKG-2109ROR25

FLOW SENSOR / 240VAC 5-55l/min 1NO

VKG-2110R0R25

(Flowmeter / guardian viscosity compensated)

VKG-Y19406 / MS08

. (Viskositätscomp flowmeter -u.Wächter measuring u.Schaltbereich: 0.2-0.8 l / min. Oil Meßstoffber.Teile: brass, Perbunan, Duran)

VKM

flow sensor

VKM1102R0R080B

Flowswitch viscosity compensated in the range 1 ... 540mm2 / s Mounting position any material brass NBR, oxide Mb: 0.1 ... max 0.45 l / min oil. 250 bar, max. 100 ° C 1 closing contact max 250VAC / DC Max. 240 VA / Watt: 1.5 A DIN 43650 G 1/4 IG without option flow direction from bottom to top RoHS compliant standard.

VKM1103R0R080B

Flowswitch viscosity compensated in the range 1 ... 540mm2 / s Mounting position any material brass NBR, oxide Mb: 0.2 ... 1.2 l / min max oil. 250 bar, max. 100 ° C 1 closing contact max 250VAC / DC Max. 240 VA / Watt: 1.5 A DIN 43650 G 1/4 IG without option flow direction from bottom to top RoHS compliant standard.

VKM3212RRR250B

Durchflussmesser/waechter

VKM8209CORR20L

FLOW SWITCH Viscosity COMPENSATED IN 1 ... 540MM2 / S MOUNTING POSITION ANY MATERIAL STAINLESS STEEL FPM oxide ceramic MB: 4 ... 36 1 / MIN MAX OIL. 350 bar; MAX 100 ° C COMPACT ELECTRONIC 24 V DC "X PNP CONNECTION G 3-4 IG FLOW FROM LEFT TO RIGHT ROHS COMPLIANT STANDARD VERSION

VKP-1020R250

viscosity Compensated

VKP-1035

Digital Oil Display SENSOR part

VKP-1035

Model: 160E .Digitale Ölanzeige

VKP-1035R250

Viskositätskomprensierter plastic Durchflussm.

VKP-1035R250.

Viskositätskomprensierter plastic Durchflussm.

Contact us for request